Instructor Manual For Bailey and Scott's Diagnostic Microbiology, 16th Edition Patricia M. Tille __________________________________________________________________
Part A-E Tille: Bailey & Scott’s Diagnostic Microbiology, 16th Edition Laboratory Manual—Part A The material in this manual is designed to be a supplement to the textbook, Bailey and Scott’s Diagnostic Microbiology, 16th Edition.
PART II: General Principles in Clinical Microbiology The material in this chapter reviews the fundamental technical aspects of medical bacteriology. It provides a basic overview of the techniques essential in the study of bacteria, such as cultivation, microscopy, and macroscopic morphologic characteristics of bacteria. This section establishes the basic principles and techniques on which the more advanced concepts of clinical bacteriology are built.
Safety in the Bacteriology Laboratory The exercises included in this laboratory manual require the handling of both nonpathogenic and potentially pathogenic bacterial and fungal microorganisms. The species that have been included are limited to organisms that should not pose a threat to healthy individuals if the students adhere to the safety guidelines. It is important to follow the safety guidelines included here, as well as those provided by the course instructor.
Laboratory Safety Guidelines 1. Proper laboratory attire Fluid-resistant laboratory coats must be worn at all times. No open-toe or open-heel shoes are permitted. Long or dangling jewelry is not permitted. Hair below the collar should be pulled back to prevent interference with the handling of samples.
2. Proper hygiene and personal cleanliness
Hand washing: Students should wash their hands upon entering the laboratory, after removing gloves, and prior to leaving the laboratory.
3. Proper maintenance of laboratory work areas Disinfect the laboratory workspace upon entering the laboratory, whenever contamination is suspected, and prior to leaving the laboratory. Properly dispose of contaminated material in the proper receptacle for contaminated waste. Do not discard infectious materials in the garbage can or the sink. Keep the work area free of clutter and any unnecessary objects.
4. Proper handling of specimens and work practices Do not recap needles. Discard the needle in an approved sharps container. Wear gloves when handling patient samples. Use a shield or other protective device if splashing of blood or body fluids is possible. Place all tubes in a rack; do not leave them unsupported or lay them on the bench top. After incineration, allow loops to cool completely before inserting in a broth or touching contaminated media to avoid the production of aerosols. Avoid stacking agar plates without a proper rack. Do not eat, drink, or apply cosmetics in the laboratory. Avoid putting anything (e.g., fingers, pens, pencils) in your mouth, eyes, ears, or touching any unexposed areas of your body while in the laboratory. A biological safety cabinet should be used for any procedure that may produce aerosols, such as vortex missing or sonication. Treat ALL patient specimens as infectious material.
5. Proper reporting of exposure incidents Promptly report any accident or spill to the instructor immediately. Spills should be cleaned by placing paper towels over the spill, soaking up the contaminant, and then cleaning the area with a disinfectant.
Broken glass should be picked up using a broom and dustpan. Discard broken glass in the proper receptacle.
Laboratory I: Basic Media, Streaking for Isolation and Colonial Morphology Objectives: 1. Define medium (plural, media) and identify a variety of media for the isolation of bacteria including enrichment, selective, nutritional, and differential. 2. Explain the significance of the utilization of different oxygenation requirements for microorganisms as demonstrated as growth in a deep or broth media. 3. Describe the semi quantitation method utilized when streaking clinical samples for isolation and identification of microorganisms. 4. Describe and interpret growth characteristics (i.e., colonial morphology) of microorganisms following incubation, including margin, color or pigmentation, opacity, consistency, odor, elevation, on various media. 5. Describe and properly perform inoculation and interpretation associated with the techniques for inoculating broths and plates. 6. Explain the significance of obtaining a pure culture from a specimen using the semiquantitative streaking technique.
Reference: Bailey and Scott’s Diagnostic Microbiology, 16th Edition, Chapter 5: Specimen Management and Chapter 7: Traditional Cultivation and Identification.
Microbial Specimens and Media Microorganisms are received in the diagnostic laboratory from a variety of human specimens. When a patient arrives at the health care facility with an infectious agent, the organism must be cultivated and separated or isolated from the large community of microorganisms that may grow in or on an individual. The organisms that normally reside on a patient but fail to cause disease are referred to as the individual’s normal microbiota. These specimens are used to culture and examine the organism’s gross morphology, referred to as colonial morphology.
Culturing or growing microorganisms in the laboratory, requires that they must be provided with the proper nutrients, moisture, and temperature. The necessary nutrients for growth vary for different microorganisms but include proteins, carbohydrates, minerals, vitamins, and may require nutritional supplements. The formulations or complex mixtures of these components are referred to as culture medium (plural-media). Media may be prepared in a variety of consistencies. A liquid culture is a broth. Solid media is prepared by mixing a broth with a compound known as agar, extracted from the cell walls of the brown algae, Phaetophyta. Solid media may then be placed into a variety of containers, including a flat petri dish, agar plate; a tube with a flat surface, deep; and a tube with a slanted surface, referred to as a slant. A broth may also be used to make a media that is referred to as a semi-solid media. This type of tube media contains a lower percentage of agar (<1%) than a solid media (1% to 3% agar). These types of media may be used to identify motility such as in a gelatin tube or reduce oxygen concentrations and diffusion such as in a thioglycolate semisolid broth tube.
Organisms that have been inoculated into a broth or agar deep provide an indication of the organisms’ oxygen requirements. Organisms that grow on the surface of the media require oxygen (aerobic) for growth. Organisms that grow only in the bottom of the tube (anaerobic) do not require oxygen for growth. Organisms that are capable of growth throughout the medium may be microaerophilic, aerotolerant, or facultative anaerobes. Organisms that grow best in higher CO2 concentrations than is provided in ambient air are considered capnophilic.
Media are categorized according to their function and use. In diagnostic bacteriology, there are four general categories of media: Enrichment—this media contains specific nutrients or growth factors to enhance the growth of a specific microorganism from a mixture of organisms. (back-up broths or enrichment broths) Nutritive—this media is supportive media that provides for the growth of most nonfastidious organisms Selective—this media contains one or more agents, including chemicals such as dyes, bile salts, alcohol, acids, growth factor and antibiotics to select for the growth of specific organisms to the disadvantage of others Differential—this media uses a biochemical factor often coupled with a color indicator to allow organisms to exhibit an identifiable metabolic or culture characteristic to differentiate the organism from other organisms growing on the media Combination Media -diagnostic media that provides more than one function or is a combination of differential and selective properties for a specific organism or group of organisms.
A more detailed explanation and summary of artificial media used for routine bacteriology is included in the textbook, Table 7-1.
Sterilization of Inoculating Instrument Prior to a specimen being received in the laboratory, the specimen must be properly collected from the appropriate anatomical site, transported properly and be of minimal acceptable quality to ensure integrity of the sample. Specific specimen management and collection procedures are outlined in Chapter 5 of the text.
When a specimen is received in the microbiology laboratory, it is important for the laboratory to protect the environment from contamination by any infectious agents in the sample and protect the sample from contamination by infectious agents in the immediate environment. This is accomplished through good aseptic and pure culture techniques.
Transferring infectious agents from a sample to a culture media requires an inoculating instrument that may be a metal loop or needle (i.e., nondisposable) or a sterile plastic (i.e., disposable) loop. Nondisposable instruments are sterilized before and after each time the instrument is placed in contact with a potentially infectious sample. The loop or wire is placed directly into an electric incinerator (open flames are not typically permitted in modern microbiology laboratories). The wire is heated starting at the junction of the wire and the handle. The wire should be heated until the wire demonstrates a red glow. The wire should be slowly retracted heating all the areas of the wire from the handle to the end of the instrument to remove all potential contaminating organisms. Carefully remove the heated wire from the incinerator and allow the wire to cool naturally. Refrain from waving or moving the wire through the air to avoid potentially contaminating the instrument.
Once the instrument has cooled, the microbiologist may place the end of the loop or wire into the sample, and then proceed to place the sample onto the appropriate culture media. It is important to never touch the sample or specimen with a hot loop or wire, as the heat from the instrument may kill viable organisms present in the sample. In addition, depending on the type of sample, placing a hot wire or loop into the sample may result in creating dangerous aerosols spreading infectious organisms into the environment.