Solution and Answer Guide: Simmons/Vigstol, Electrical Wiring Residential, 21E, ©2024, 9780357766972, Chapter 2: Specifications, Electrical Symbols, and Outlets
Solution and Answer Guide ELECTRICAL W IRING RESIDENTIAL 21ST EDITION RAY C. MULLIN, PHIL SIMMONS, DEREK VIGSTOL CHAPTER 1: GENERAL INFORMATION FOR ELECTRICAL INSTALLATIONS TABLE OF CONTENTS Review ............................................................................................................................ 1 Safety-Related Problems .............................................................................................. 5
REVIEW Refer to the NEC or the plans in the back of this text where necessary. 1. What code sets the standard for electrical installation work in the United States? ________________________________________________________________ ____________ Answer: The NEC is the basic standard; local and state codes are to be considered also. 2. What entity enforces the requirements set by the NEC? ________________________ ________________________________________________________________ ____________ Answer: The local electrical inspection authority or Authority Having Jurisdiction(AHJ) 3. Does the NEC provide minimum or maximum standards? ________________________ Answer: Minimum 4. What do the letters ―UL‖ signify? ________________________________________________________________ ____________ Answer: When shown on an electrical product or in a certification mark, it means the product is Listed by Underwriters Laboratories. It also means that the product met applicable safety standards when it left the manufacturer’s plant.
© 2024 Cengage. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
1
Solution and Answer Guide: Simmons/Vigstol, Electrical Wiring Residential, 21E, ©2024, 9780357766972, Chapter 2: Specifications, Electrical Symbols, and Outlets
5. What section of the NEC states that all listed or labeled equipment shall be installed or used in accordance with any instructions included in the listing or labeling? ________________________________________________________________ ____________ Answer: NEC 110.3(B) 6. When the word ―shall‖ appears in an NEC reference, it means that it (must)(may) be done. (Select the correct word.) Answer: Must 7. What is the purpose of the NEC? What section can this statement be found in? ________________________________________________________________ ____________ ________________________________________________________________ ____________ ________________________________________________________________ ____________ ________________________________________________________________ ____________ ________________________________________________________________ ____________ ________________________________________________________________ ____________ Answer: The NEC states in 90.2(A) that ―The purpose of this Code is the practical safeguarding of persons and property from hazards arising from the use of electricity.‖* 8. Does compliance with the NEC always result in an electrical installation that is adequate, safe, and efficient? Why? ________________________________________________________________ ____________ ________________________________________________________________ ____________ ________________________________________________________________ ____________
© 2024 Cengage. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
2
Solution and Answer Guide: Simmons/Vigstol, Electrical Wiring Residential, 21E, ©2024, 9780357766972, Chapter 2: Specifications, Electrical Symbols, and Outlets
________________________________________________________________ ____________ Answer: No. The NEC states in 90.2(B) that ―This Code contains provisions that are considered necessary for safety. Compliance therewith and proper maintenance results in an installation that is essentially free from hazard but not necessarily efficient, convenient, or adequate for good service or future expansion of electrical use.‖* Informational Note: Hazards often occur because of overloading of wiring systems by methods or usage not in conformity with this Code. This occurs because initial wiring did not provide for increases in the use of electricity. An initial adequate installation and reasonable provisions for system changes will provide for future increases in the use of electricity. 9. Name two nationally recognized testing laboratories. ____________________________ ________________________________________________________________ ____________ ________________________________________________________________ ____________ Answer: Underwriters Laboratories (UL) and Intertek Testing Services (ETL listing mark). There are other testing laboratories such as Canadian Standards Association (CSA), Factory Mutual (FM), and others the student might refer to that may be acceptable to the authority enforcing the Code.
10. a. Do Underwriters Laboratories and the other recognized testing laboratories ―approve‖ products? _______________________________________________________ b. What do these testing laboratories do? _______________________________________ ______________________________________________________________ _____________ ______________________________________________________________ _____________ ______________________________________________________________ _____________
© 2024 Cengage. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
3
Solution and Answer Guide: Simmons/Vigstol, Electrical Wiring Residential, 21E, ©2024, 9780357766972, Chapter 2: Specifications, Electrical Symbols, and Outlets
Answer: a. No. Approval is up to the Authority Having Jurisdiction. See NEC 90.4 and 110.2. b. They test the products for conformance to applicable product safety standards. When the product passes these tests, the manufacturer of the product is then permitted to affix a ―label‖ (often referred to as a ―listing mark‖) that indicates the product complied with the applicable safety standard when it left their factory. 11. a. Has the NEC been officially adopted by the community in which you live? b. By the state in which you live? c. If your answer is YES to (a) or (b), are there amendments to the NEC? d. If your answer is YES to (c), list some of the more important amendments. Answer: Student answers will vary, depending on where this course is taught. The questions refer to local issues. 12. Does the NEC make suggestions about how to wire a house that will be occupied by handicapped persons? _______________________________________________________ Answer: Informative Annex J includes information that is intended to assist the users of the Code in properly considering the various electrical design constraints of other building systems and are part of the 2010 ADA Standards for Accessible Design. The Informative Annex is not enforceable. The basic NEC rules still apply. Local communities, counties, states, and/or other govern-mental bodies might have requirements. Check with your local inspection authority. Ask them if there are any requirements or suggestions that you might need to follow. 13. A junction box on a piece of European equipment is marked 344 cm 3. Convert this to cubic inches. (Hint: Is there a table that lists standard box sizes?) ___________________ ________________________________________________________________ ________________ Answer: 200
0.06102 = 12.204 cubic in.
14. Convert 4500 watts to Btu/hour. _________________________________________________ ________________________________________________________________ ________________ Answer: 4500
3.4129 = 15.358 Btu/hour
© 2024 Cengage. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
4
Solution and Answer Guide: Simmons/Vigstol, Electrical Wiring Residential, 21E, ©2024, 9780357766972, Chapter 2: Specifications, Electrical Symbols, and Outlets
15. You will learn in Chapter 3 that residential lighting loads are based on 3 voltamperes per ft.2 (33 volt-amperes per m2). Determine the minimum lighting load required for an area of 186 m2. Do calculations for both feet squared and meters squared so you can see the difference in answers. To convert meters squared to feet squared, refer to Table 1-8. ________________________________________________________________ ________________ ________________________________________________________________ ________________ ________________________________________________________________ ________________ Answer: Step 1: Convert square meters to square feet 186
10.764 = 2002 sq. ft
Step 2: 2002
3 = 6006 volts-amperes
Working in metrics, the answer is 186
33 = 6138 volt-amperes
Note: This is an excellent example of what happens when converting inch-pound units to metrics, or vice versa. You can see that the NEC decided to ―round-off‖ 3 volt-amperes per sq. ft to 33 volt-amperes per square meter. The result is different answers. Not a big difference, but different nevertheless. Converting a rounded-off inch-pound number to metrics always results in a fractional metric value. Converting a rounded-off metric number to inch-pound units always results in a fractional inch-pound value. There is no easy way to resolve this issue. Just follow the values as found in the NEC. No doubt inch-pound measurements will be used in this country for quite a while, so use the inch-pound values until such time that more information becomes available as on how to handle conversions in the NEC. See Tables 1-6, 1-7 and 1-8 in Electrical Wiring Residential. There is also a comprehensive inch-pound/metric conversion table in Appendix D of Electrical Wiring Residential. Refer to it often. SAFETY-RELATED PROBLEMS 16. What federal organization dictates requirements for work-related safety issues? (Select the correct answer.)
© 2024 Cengage. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
5