Skip to main content

ARCH 5120 Comprehensive Design Nested Systems

Page 1

NESTED SYSTEMS Serena Liang + Kathryn Platt ARCH 5120 spring 2020 Studio Instructor - Michael LeBlanc


THE EXQUISITE


Statement From the beginning, our exploration has been about calibrating and optimizing the space created between the two hybrid structural systems. While the inner structure provides space for most of the functional, day-to-day uses, the interstitial space is what makes the building endure over time. The interstitial space gives climatic control and flexibility in building uses: • It is passively heated, cooled, and ventilated, which is perfectly acceptable for inhabitants who spend only a short period of their day in this space and means there’s no HVAC equipment to have to maintain or update. • It is treated at the scale of a landscape and can have a different maintenance and cleaning regimen than the inner, more pristine spaces. The flexibility provided by these varied interstitial spaces increases building resiliency of adapting changes in the future of uncertainty. To response to the three scenarios and program uses we chose to study: 1. An academic building can have its classes in the compact space, and open up onto an indoor campus where larger civic gatherings can take place. 2. A fabrication space often has lots of small equipment, which can go in the inner spaces, while there are a few pieces of larger equipment that are installed in the high bay. 3. A temporary hospital can allow patients to spend time in a setting that feels like it’s outdoors, while keeping them safe and separated in the middle of the city.


Allston, MA | Harvard Campus Expansion

Avenue Western

ad

Field Ro

Charles River

Soldiers

N Our Building Existing Buildings Master Plan Buildings Master Plan Greenway

The Greenway connecting the new Harvard Allston Campus 1


HBS

N

1/64” = 1’-0” re Central Squa E

VENU WESTERN A earch Campus

ELD ROAD

e Gr

ay w n e

SOLDIERS FI

(NEW) EASTERN ST

Enterprise Res

2


View from Memorial Drive 3


Interior View 4


Interstitial Space Flexibility - Civic Use as Public Park 5


Interstitial Space Flexibility - Fabrication Use - Multipurpose Roof Deck 6


Program Flexibility - Civic Use 7


Program Flexibility - Fabrication Use 8


1

2

3

40’

1

6

4

’

100

5

60’

’

145

50’

Outer Steel Structure - Type II 1 2 3 4 5 6

Open Web Joists spaced every 12 feet Truss Girders 65-foot Column with a max tributary area of 3,000 sf Double-Column braced for North-South lateral forces Cable Bracing for East-West lateral forces Concrete Slab

ING

D LOA

FIR

1

EL AN

E

2 2

3 4

N Scale 1/48” = 1’-0”

9

Minimum Number of Exits per Story

Exit Access Travel Distance

Occupant Load per Story 1-500 501-1,000 More than 1,000

Occupancy

Minimum Number of Exits 2 3 4

Egress Widths of 0.3” per occupant

H-1 - H-4 H-5, I-2, I-3, I-4 A, E, F-1, I-1, M, R, S-1 B F-2, S-2, U

With Sprinkler System (linear feet) 75 - 175 200 250 300 400

Allowable Area* Max number of stories = 4 Max area = 76,500 sf

20’

25’

* Based on Type IV Education use

Actual Area Stories = 4 North Building = 71,147 sf South Building = 35,348 sf

Inner Heavy Timber Structure - Type IV 1 2 3 4

Cross-Laminated Timber (CLT) Floor 1-foot deep Glulam Beams 16-foot Glulam Column with a max tributary area of 500 sf Glulam Bracing to balance the lateral system, at least every 5 bays


’4

from Solar ity

’4

nels Pa

Elect ric

Winter

’4

F Po w er

’4

DE

Components

15 15

5f ee t

t fee

60

’5

Low-E Double-Pane Glass Light Transmission: 70%

t fee t ee 5f

fee t

Tinted Polycarbonate Light Transmission: 42%

3 2

’4

N

’4 ’4 ’4

Summer

ity

Siz es +

G

1 S ite C

IN SK

ll Wa

d oun 3 S OLAR CONTROL Year-R

embly Ass

2 I NS UL AT I

R Value

Siding Vertical Spacers Air and Moisture Barrier Sheathing Batt Insulation Gypsum Wallboard

0.8

een Gr

+

use Re

Rainw a

Aggregate - gravel in asphalt

llec r Co tion te

Bio

s wales

Membrane - gypsum board Rigid Foam Insulation Board Corrugated Steel Deck

f Assembly Roo

1 19 0.5

1/2” 1/2”

NG IN

6” 3/8”

Wall Assembly

SK

1/2”

’5

irculation

1

INS UL AT IN

KE YC av

10


Fabrication Use

Overpopulation Scenario

Urban Farming Scenario

Instructional Use

Atrium space can transform into a high bay to host tall, heavy equipment

Additions of interior bays

Roof becomes production site

Higher-than-average occupancy

A More structural durability

C 3 egress cores allowing increase in occupancy for different uses

B Roof panel demountability

Heat Recovery Unit

N

rating electricity PV panels gene

B

Sp rin kle r

Ventilation Duct

Administrative - open office

Educational

1

- lecture hall

Solar Inverter Solar Battery C

2 5 Fan Coil Terminal

3

Fabrication

- maker space

Variable Flow

16 feet floor-to-ceiling height allows flexibility for use change

4

Harvard District Energy Facility (DEF)

Heat Exchanger

A

Hot water Chilled water

Active Comfort Systems Decoupling of Ventilation and Heating/Cooling Use of district heating and cooling makes the building’s system less complex and less expensive. Distribution pipes and ducts are hosted within the inner structure.

7

6

3 1 2 5

4

11

8

Flexible Interior Structure

Passive Comfort Systems

Flexible Exterior Envelope

Experiential Acoustics

Durable Interior Envelope

Durable Exterior Structure

Repetitiveness of modules allows for addition and subtraction of bays.

The interstitial spaces are heated, cooled, and ventilated passively. This reduces overall building energy loads by mitigating the extremes against which the active systems of the inner spaces have to work. In times when it’s unsafe of unfitting to go outside, this space fulfills occupants’ desire for a more natural environment.

3 Glass and polycarbonate louvers can be opened, maintained and replaced as needed.

6 Spaces of different noise levels are separated by the interior insulating wall with double-glazed glass.

As the insulating envelope, this layer is less interchangable. It allows in regular amounts of daylight and will be equipped with motorized blinds that occupants can override.

A The steel structure withstands the changing of its facade and of the inner structure.

1 bottom layer CLT 2 middle layer CLT 3 services in ceiling trough including sprinklers 4 acoustic insulation between CLT 5 services in floor trough 6 acoustic underlayment gypcrete 7 hardwood finish floor 8 lighting

Modulating the size of the cavity allows for ventilation as well as a range of occupiable spaces. 1 Stack Effect 2 Venturi Effect prevention with trees at either end of the walkway and operability of louvers where needed.

4 Garage doors into large spaces allow for movement of large machinery B Demountable roof panels

atrium sound

Experiential Lighting 5 The interstital spaces are treated at the scale of a landscape, with street and path lighting.

sound is reflected

spacer to create air space

sound is absorbed by interior finishes see phase 2 wall assembly for details

Frost wall at the perimeter.


RECEPTION

KITCHEN STORAGE

OPEN OFFICE

COLAB

COLAB

STORAGE

CAFE

COLAB OFFICE HIGH BAY

ROBOTICS LAB

MAKER SPACE

HIGH BAY

OFFICE

LOADING DOCK

MAKER SPACE

STORAGE

Total Area = 129,214 sf Program Area = 116,095 sf Floor-Area-Ratio = 1

N

1/32” = 1’-0” 12


Layering Sequence 13


Index

14


Structural Concept - Exterior Steel & Interior Wood 15


Envelope Concept featuring 1/8� model 16


Envelope Concept featuring 1/8� model 17


18


19


20


The Start/End of the Greenway 21


Entering West Plaza 22


Interstitial Space - Vertical Circulation 23


Interstitial Space - Courtyard 24


South

North

Elevations 25


1/32” = 1’-0”

West

East

Elevations 26


Pandemic

Urban Farming

total ~ 1,000 patients Patient Zone 30,000 sq ft (300 ppl)

Population Growth

Clear Seperation / Safe Living Distance

12,600 sq ft Medical Worker Housing Zone

Fabrication

Administrative Structural Flexibility to change between office layouts Enclosure Access to windows and views All exterior envelope glazing has shading Temperature Individualized climate control 20-60% humidity 27

Ventilation Indoor air quality monitoring The workplace CO2 exposure limit in most jurisdictions is 5,000 ppm for an 8 hour period

Structural Typical loads of 250 lb/sf stored materials and equipment

Acoustics Small conference rooms NC 30-35 Small private offices, libraries NC 30-35 General offices NC 35–40

Service 100% exhaust from moderate hazard storage conditions Carbon monoxide detectors

Enclosure Provide adequate daylighting Provide dust control and natural ventilation

Instructional Structural Movable partitions accommodate a wide variety of group learning sizes. Enclosure Moderate visual openness and acoustical privacy Install proper sun control and shading devices to reduce glare Comfort Systems Allow for individually controlled temperature and lighting. Ensure fresh air intake and adequate ventilation High-performance HVAC zoned for varying occupancies


Turn static files into dynamic content formats.

Create a flipbook
ARCH 5120 Comprehensive Design Nested Systems by Northeastern School of Architecture - Issuu