11.2026 Foster + Partners A Beacon of Knowledge Mariam Vaid - Saamiya Pathan
American University of Sharjah ARC 382
Climate-Adaptive Facades
16
Documentation
11.2026 ARC 382
The facades of the towers comprise of mechanised structures that adapt to the movement of the sun. The original folding concept for the dynamic mashrabiya unit was initially explained through a simple origami model that revealed how the triangular unit would function. The shading system was then developed by the computational design team at Aedas, where they used a parametric description for the geometry of the actuated facade panels, enabling them to simulate their operation in response to sun exposure and changing incidence angles during the different days of the year. Each sun shading device is driven by a linear actuator to protect the building from excessive exposure to solar rays.
Section of Al Bahr Tower Scale - 1:60 Drawn By: Mariam Vaid
M
AHR UK
D
E
19
F
ARC 382 Key 1. Perimeter Edge Beam: Structural steel I-beam (grade S355) with profiled steel decking and reinforced concrete topping. 1500
2. Suspended Ceiling & Service Zone: Perforated acoustic metal ceiling panels on galvanized steel hangers concealing HVAC ductwork, sprinklers, and MEP services.
1
3.Interior Balustrade: 10+10 mm laminated toughened
8 2
2000
clear glass in brushed stainless steel base shoe with tubular stainless steel top handrail (1,100 mm high). 4.Facade Support Brackets: Galvanized steel cast-in channels and serrated structural brackets anchoring the curtain wall to the slab edge. 5.Interior Floor Finish: 600 × 600 mm high-density
9
calcium sulfate raised access floor panels on adjustable galvanized steel pedestals with carpet/stoneware finish. 3700
6.Structural Floor Slab: 300 mm thick post-tensioned reinforced concrete slab with perimeter mineral wool fire-stopping insulation.
10
7.Foundation / Substructure: Waterproofed reinforced concrete raft foundation, basement retaining wall, and ground-level BMU maintenance track curb. 3
8.Cantilevered Steel Supports: Custom-fabricated marine-grade duplex stainless steel hollow-section outrigger 1800
4
struts with pinned clevis joints. 9.PTFE-Coated Fiberglass Mesh: Translucent, micro-perforated Polytetrafluoroethylene (PTFE)-coated woven
11
fiberglass tensile infill panels. 10.External Kinetic Mashrabiya Shading Screen: Anodized aluminum triangular sub-frames arranged in hexago-
12
nal modular clusters (~4,200 mm module height). 11.Kinetic Shading Mechanism / Actuator: Electrically 4500
driven linear screw-jack actuator in a dust-sealed stainless steel casing with scissor-arm linkages and PTFE bearings. 12.Curtain Glass Wall: Unitized low-iron double-glazed units (DGUs) with solar-control low-E coating, argon cavity, and thermally broken anodized aluminum mullions
5
6
800
2200
7
Section of Al Bahr Tower Scale - 1:75 Drawn By: Saamiya Pathan
Drawing:
Sources: House of Wisdom 1. Foster + Partners. House of Wisdom, Sharjah. 2. ArchDaily. House of Wisdom Library and Cultural Center / Foster + Partners. 2021. 3. Identity.ae. Foster + Partners completes House of Wisdom library in Sharjah. 4. Chris Goldstraw. House of Wisdom, Sharjah. Architectural photography. Al Bahr Towers 5. AHR. Al Bahr Towers. 6. ArchDaily. Al Bahr Towers Responsive Facade / Aedas. 7. Aedas. Al Bahr Towers — Origami Concept and Geometrical Experimentation. Reproduced in Parametric Architecture. 8. Arup. The Arup Journal 2013/2. Al Bahr Towers project documentation.
CORNER DETAIL - EXPLODED AXONOMETRIC 01
SCALE: 1:75
22
Documentation
11.2026 ARC 382
3
80
4
70
2
5
130
7
6
250
9
110
8
10 11
300 Section Detail 1:5 Drawn By: Saamiya Pathan KEY 1 - RC Upstand 2 - Waterproofing membrane 3 - Floor finish 4 - Screed 5 - Filter Layer + Roof insulation 6 - Structural thermal break in concrete 7 - RC roof slab 8 - Suspended Ceiling 9 - Steel RHS mullion 10 - Double Glazed Unit 11 - Vertical louvre 12 - Louvre stainless steel pivot/fixing 13 - Floor finish 14 - Screed 15 - Rigid floor insulation 16 - RC ground floor slab 17 - External lining: waterproofing, insulation 18 - Binding + waterproofing under raft
Saamiya Pathan
23 ARC 382
1
2 3 4 5 6 7 8 9
80 100 175 175 50
10 2100
11 12 13 14 15
50 150 50 130
16 17
600
18 130
Section Detail 1:20 Drawn By: Saamiya Pathan
24
Documentation
11.2026 ARC 382
3 4 2 5
7
6
8 9
10
11
Axonometric of 1:5 section Drawn By: Saamiya Pathan
Saamiya Pathan
25 ARC 382
1
2 3 4 5 6 7 8 9
10
11 12
13 14 15
16 17 18
KEY 1 - RC Upstand 2 - Waterproofing membrane 3 - Floor finish 4 - Screed 5 - Filter Layer + Roof insulation 6 - Structural thermal break in concrete
Axonometric of 1:20 section Drawn By: Saamiya Pathan 7 - RC roof slab 8 - Suspended Ceiling 9 - Steel RHS mullion 10 - Double Glazed Unit 11 - Vertical louvre 12 - Louvre stainless steel pivot/fixing
13 - Floor finish 14 - Screed 15 - Rigid floor insulation 16 - RC ground floor slab 17 - External lining: waterproofing, insulation 18 - Binding + waterproofing under raft
26
11.2026
Documentation 90
120
ARC 382
1
5
6
7
120 20 8 9 21 13
25 75
14 15 16
22
400
50
200
650
Detail 01 )1:5)
Key 1- Fascia Panel 2- 100 MM Concrete Deck 3- 50 MM Acoustic Insulation 4- 120 MM Truss Top Chord 5- 120 MM End Post 6- 60 MM Diagonal Web 7- 120 MM Truss Bottom Chord 8- 25 MM Head Plate 9- M16 Bolts 10- Services Duct 11- Ceiling Hanger Rods
12- Suspended Ceiling, 20 MM plasterboard 13- 200 MM Steel Column 14- Aluminium Louvre Fin 15- Mullion 16- Double-Glazed Unit 17- 20 MM Floor Finish 18- Steel Floor Frame 19- Steel Support 20- 25 MM Bearing Plate 21- 10 MM Stiffener Plate 22- 10 MM EPDM Gasket
Mariam Vaid
27 A
150
1 2 3 4
ARC 382
5
900
Detail 01
6
10 11
490
7 8 9
12
13
14
17 2 3 18 19 9
Building Section (1:20)
440
16
2710
15
Mariam Vaid
29 ARC 382
5 1
6
7
20 8 9 21
14 15 13
16 22
Detail Axonometric (Not to Scale)