Thinking in Assemblies
Using Wall Sections to Make Better Material Choices
Thinking in Assemblies
Using Wall Sections to Make Better Material Choices authors
Contributors
April 2016
Christopher Lee, LEED AP BD+C Re:Vision Architecture
Christopher Boccella CVMNEXT Construction
for more information contact: info@revisionarch.com
Nicole Campion, PhD, LEED GA
Garrett McKissock SIGA Ethan Lee Swarthmore College
Abstract Assemblies, like the wall section, are fundamental to how we think about and construct our buildings. They have a significant impact on a project’s operating energy and embodied carbon footprint (ECF). Traditionally, material selection has been driven by performance, cost, and aesthetics; however, the emerging focus on environmental and health transparency tools is beginning to transform the industry. Designers, contractors and developers are beginning to consider new priorities like lifecycle assessment, toxicity, and moisture transport as they select materials.
While minimizing operating energy is still the primary design strategy for high performance buildings, minimizing embodied carbon is also becoming important to clients and designers. This study puts particular emphasis on embodied carbon footprint modeling to better understand its role in the decision making process for materials. The research had two parts:
Part One To better understand how to take a more holistic approach to product selection, this study evaluates and compares 12’H x 24’W wall sections of varying construction materials. Each assembly was evaluated using a multi-attribute analysis that included the following metrics:
Embodied Carbon Footprint (ECF) Materials Toxicity Moisture Transportation Thermal Resistance End of life Impact Cost
• Develop a holistic methodology for multi-attribute assessment of a wall assembly and its individual components given evolving priorities towards the environment and health. • Assess how built wall sections perform against the new criteria and how they could be improved to lower embodied carbon, adhere to Red List compliant chemicals, and/or reduce their contribution to land fill waste at the end of their useful life.
Part Two • Create wall sections of similar thermal resistance and construction type, to evaluate insulation within the new sets of environmental and health criteria.
Contents INTRODUCTIONÂ............................................................................................................................. 2 METHODOLOGY............................................................................................................................. 4 STUDY OF FIVE SECTIONS............................................................................................................. 8
DESIGN DECISION ............................................................................................................. 8
Embodied Carbon Footprint...................................................................................... 10
Material Toxicity and Transparency............................................................................ 16
Moisture Performance............................................................................................... 20
Thermal Performance................................................................................................ 22
Material Cost.............................................................................................................. 23
End-of-Life.................................................................................................................. 24
DESIGN DECISION ANALYSIS............................................................................................ 26
Design Decision of Five Wall Sections....................................................................... 26
STUDY OF FIVE SECTIONS CONCLUSION........................................................................ 30
NORMALIZED SECTION STUDY................................................................................................... 34
NORMALIZED SECTION STUDY ANALYSIS....................................................................... 34
Embodied Carbon Footprint...................................................................................... 36
Material Toxicity and Transparency............................................................................ 40
Thermal Performance................................................................................................ 42
Material Cost............................................................................................................. 43
End-of-Life................................................................................................................. 44
DESIGN DECISION ANALYSIS........................................................................................... 46
Design Decision of Normalized Wall Study............................................................... 46
NORMALIZED SECTION STUDY CONCLUSIONS............................................................. 50
Collaborators................................................................................................................................ 51 References................................................................................................................................... 51
page 2
INTRODUCTION The idea for “Thinking in Assemblies” began as most ideas do, with a conversation about potential and possibility. Within Re:Vision Architecture, we were meeting with a number of manufacturer’s sustainability managers and product managers. We talked with these sustainability professionals about third party reporting methods and certifications such as Health Product Declaration, Environmental Product Declaration, MSDS, the Declare Label, Cradle to Cradle, and the overall importance of ingredients and environmental transparency in the building industry. Through these conversations, we learned of uncertainty about knowing which third party certification would become important in the marketplace, which ones were worth putting resources behind, and hesitation to participate in third party reporting due to the required disclosure of proprietary ingredients. We also shared some barriers to conducting materials transparency research as required for Living Building Challenge (LBC) projects: the time, finding the right resources, and finding and talking to the right person within companies to get information needed to complete LBC documentation. We all wanted a single resource, a single tool, or a single certification that would aggregate all of a product’s attributes and environmental impacts in one place. We knew the “Living Product Challenge” by the International Living Future Institute was due for release which would begin to collect this data. However, we didn’t know how quickly it would be adopted by the building industry so we decided to see if aggregating multiple tools available today
could get us closer to this goal. The research of “Thinking in Assemblies” is a proposal for a methodology for the holistic and transparent analysis of materials. We aim to take off the single attribute blinders traditionally used to evaluate materials and provide a wide look at the impacts our material selection has across multiple metrics, such as cost and performance, as well as toxicity, embodied carbon, moisture transport, and end of life.
Why Assemblies? The “Thinking in Assemblies” methodology we are proposing is about a different approach to product selection and research. Rarely is anything in the built environment made of a single ingredient or product, so why do we approach materials research and selection at the product level? We should research like we build and think in terms of building assemblies. By zooming out to this larger scale, we believe the proposed methodology can be more valuable in the process of material selection for buildings. Wall assemblies are high impact in terms of cost, performance and the sheer amount of materials used. For this reason, wall assemblies are an ideal place to begin to reduce environmental and health impacts.
page 3
Why should you care?
There are many reasons but, for us, it comes down to three key issues.
responsibility As designers, contractors, engineers, and developers, we help select the products and materials used in our buildings. Ingredients on the Red List represent some of the worst-in-class and carcinogenic chemicals that are currently prolific in the built environment because we put them in our buildings. Just as architects are responsible to provide accessibility, egress, and energy performance, we should also be mindful of selecting of materials that minimize harm to our clients and the environment throughout their lifecycle.
influence
right to know
With product selection for projects comes buying power. Buying power is one of the most influential tools we have in a market economy to help move and change the building product industry. If product specifiers favored Red List Free rigid roofing insulations, manufactures making Red List free products would see great growth, while competitor products with Red List ingredients would be faced with the decision to lose market share or adapt to the demands of the industry to remain competitive.
Nutrition labels let us know what we put into our bodies, why shouldn’t we know what is in the building products we live with each day at work, school, and home? Right now we have the ability to look at a food label and make an informed decision for our health. Most people cannot evaluate MSDS or HPD to make more informed decisions on the impact a material could have on their health. Disclosing ingredients or product life cycle impacts is good for consumers and also for manufactures so they can better understand impacts beyond their factory doors.
page 4
METHODOLOGY Each 12’H x 24’W wall section was evaluated using the below criteria as a guide for assessment.
EMBODIED CARBON FOOTPRINT (ECF) a. Embodied carbon footprint (ECF) via Athena Impact Estimator for Buildings b. Available specific and industry-wide EPDs when input was unavailable in Athena MATERIALS TOXICITY & TRANSPARENCY a. Living Building Challenge’s v3 Red List b. Available specific and industry-wide EPDs PERFORMANCE a. Moisture Transport in wall assembly assessed using USai modeling software by SIGA b. Thermal resistance per manufacturer provided information
END OF LIFE (EOL) a. End of life for the product determine by best practice and contacting manufacturers COST a. Materials cost provided by a construction cost estimator CVMnext Construction
page 5
DESIGN DECISION MATRIX A Design Decision Matrix was developed to incorporate the five metrics into a tool to score each assembly. The method for the Design Decision Matrix is as follows: - 10-points were assigned to each of the five metrics for a maximum total of 50 points per assembly. The assembly’s predicted Moisture Performance was evaluated with a pass/fail.
Criteria Points
Cost
Embodied Toxicity R-Value Carbon
End of Life
1
High
High
High
Low
Landfill
Low
Low
Low
High
Recycle
2 3
- The criteria points were determined by assessing the maximum and minimum of each of the metrics as shown in Figure 1.
4
- The following descriptions and figures assume an equal weighting across all five metrics. However, the Design Decision Matrix was developed such that the weighting of each metric could be adjusted to represent the needs and goals of the project. For example, you could weigh the matrix such that cost, toxicity, and performance were twice as important as end of life and embodied carbon.
6
5
7 8 9 10
Figure 1: Design Decision Matrix Diagram
STUDY OF FIVE SECTIONS
page 8
STUDY OF FIVE SECTIONS
interior
exterior
The following pages outline the analysis and findings of our research. The assemblies selected have been used on built projects and include all of the various insulation types.
Assembly Inventory Five unique 12’H x 24’W wall assemblies were analyzed as shown below in Table 1.
METAL STUD
WOOD STUD
CMU
Cedar Wood Tongue and Groove Siding
Exterior Paint
Stone Veneer
WD Furring Strips
Cement Fiber Board Panel
Mineral Wool Insulation
Polyiso Insulation
Metal Z Girts
Air and Vapor Barrier
Air and Vapor Barrier
Mineral Wool Insulation
CMU Block
Plywood Sheathing Spray Foam Metal Stud GWB Interior Paint
Interior Paint
DOUBLE WOOD STUD Cement Fiber Board Panel WD Furring Strips
TJI Cement Fiber Board WD Furring Strops Air and Vapor Barrier
FG Mat Gypsum Sheathing
Plywood Sheathing
Plywood Sheathing
Full Cavity DensityPack Cellulose
Air and Vapor Barrier
Air and Vapor Barrier
Plywood Sheathing
Fiberglass Insulation
Fiberglass Insulation
Wood Studs
Oriented Strand Board
Wood Stud
GWB
Deep TJI
GWB
Interior Paint
GWB
Interior Paint
Table 1: Wall Assembly Breakdown from Wall Exterior to Interior
Plywood Sheathing
Interior Paint
page 9
METAL STUD
WOOD STUD
CMU
DOUBLE WOOD STUD
TJI
page 10
STUDY OF FIVE SECTIONS Embodied Carbon footprint Athena Impact Estimator for Building User Guide Notes & Inputs
“
LCA is a predictive science with uncertainties and data gaps. It should be used as an estimating tool, not a tool that measures precisely. This means it should inform but not necessarily dictate design decisions. Most importantly, LCA addresses only some of the environmental impacts of interest in a sustainability agenda. The other impacts need to be measured with other tools. –Guide to Whole Building LCA in Green Building Programs, March 2014, pg. 27
“
”
Assumptions and uncertainties are inherent to any LCA calculation. In our opinion, some of the uncertainties have balancing effects on the results, so that the end result is still often within an acceptable margin of error. In our opinion, LCA results with the IE4B should be viewed with a 15% margin of error perspective. In other words, we consider a comparative impact measure difference of 15% or less between two design scenarios as being equal or insignificant. –User Guide September 2014, pg. 15
”
Model Inputs: - 50 year time span - Average USA data - Cradle to gate analysis - Life cycle input related to components (see Table 2)
page 11
INSULATION
Wall Assembly
Wall Material
Athena Input
Cedar Wood Tongue and Groove Siding
Cedar Wood Tongue and Groove Siding
Cement Fiber Board Panel
Fiber Cement
Stone Veneer
Natural Stone
WD Furring Strips
Small Dimension Softwood Lumber, Kiln-Dried
Air and Vapor Barrier
Air Barrier
Fiberglass Mat Gypsum Sheathing
1/2” Gypsum Fiber Gypsum Board
Plywood Sheathing
Softwood Plywood
Oriented Strand Board
Oriented Strand Board
Metal Z Girts
Bolts Fasteners Clips
Steel/Metal Stud
Galvanized Studs
Wood Stud
Small Dimension Softwood Lumber, kiln-Dried
CMU Block
8” Concrete Block
Deep TJI
Parallel Strand Lumber
GWB
5/8” Regular Gypsum Board
Interior Paint
Solvent Based Alkyd paint
Polyiso Insulation
Polyiso Foam Board
Fiberglass
FG Batt R 11-15
Mineral wool
MW Batt R 11-15
Spray Foam
Hand calculation
Cellulose
Blown Cellulose
Table 2: Athena Life Cycle Unit Processes
page 12
STUDY OF FIVE SECTIONS Embodied Carbon footprint Life Cycle Impact Assessment Results The embodied carbon totals and respective weights of the materials used in each of the five wall assemblies can be found in Figure 2. FINDINGS OVERVIEW - The mineral wool insulation had a higher embodied carbon footprint relative to its weight – showing that the weight of a product does not necessarily correlate to the embodied carbon footprint associated with the product.
- The stone veneer found in the CMU assembly, contributed to 44% of the total embodied carbon footprint. - Of the insulations used, the order of total embodied carbon footprint from high to low is:
- The spray foam found in the Metal Stud assembly and the concrete blocks found in the CMU assembly were the two materials with the highest weight and embodied carbon footprint (ECF) out of all the components analyzed.
Spray foam Fiberglass
- 3 ½” - 90 kg of CO2 eq
- Spray Foam of Assembly - Weight: 57%; ECF: 80% - Concrete Block of Assembly - Weight: 74%; ECF: 45%
Polyiso
- 1”
Cellulose
- 12” - 60 kg of CO2 eq
- Gypsum board (GWB), used in four out of five wall assemblies, averaged 12% to 20% of the total assembly weight and 2% to 13% of the total embodied carbon footprint.
- When investigating spray foam we wondered why it had the highest ECF, Spray foam typically has two sides. Side A consists of pMDI (polymeric methylene diphenyl diisocyanate) and Side B is a mixture of polyols (polyster or mannich), fire retardants (TCPP or brominated), and blowing agents (HFC). Depending on the application process, the blowing agent can have the highest contribution to ECF followed by the pMDI [1]
- Plywood sheathing, found in four out of five wall assemblies, averaged 11% to 20% of the total assembly weight and 2% to 10% of the total embodied carbon footprint. - Cement fiber board panels, found in three out of five wall assemblies, averaged 20% to 30% of the assembly weight and 25% to 30% of the total embodied carbon.
- 5 ½” - 4,059 kg of CO2 eq
Mineral wool - 5”
- 284 kg of CO2 eq - 61 kg of CO2 eq
- Per the SPFA [1], 1m2 of 1 inch thick medium density spray foam represents 27.6 kg CO2 eq.; 288 sf=26.75m2 26.75m2 x 27.6 kg CO2 eq = 738 kg CO2 eq per in. of SF 738 kg CO2 x 5 1/2” = 4,059 kg of CO2 eq
9000
6000
page 13
8000 5000
5000 3000 4000
3000
2000
2000 1000 1000
0
0 Weight
ECF
Metal Stud
Weight
ECF
Wood Stud
Weight
ECF
CMU
Figure 2: Weight and Embodied Carbon Footprint of Materials Found in Five Wall Assemblies.
Weight
ECF
Double Wood Stud
Weight
ECF
TJI
Embodied Carbon Footprint (kg CO2 eq.)
4000
Weight (kg)
weight (metric tons)
6000
embodied carbon (kg CO2 eq.)
7000
ECF
ECF
page 14
STUDY OF FIVE SECTIONS Embodied Carbon footprint
ECF
METAL sTUD assembly
ECF
6,158 kg CO2 eq.
ECF
Embodied Carbon Hot-Spots ECF 1. Spray Foam 2. Wood Siding 3. Metal Studs
2,632 kg 5,802 lbs
WOOD sTUD assembly
ECF
1,086 kg CO2 eq.
Embodied Carbon Hot-SpotsECF 1. Cement Fiberboard 2. Mineral Wool 3. Gypsum Wall Board
1,383 kg 3,049 lbs
CMU assembly
2,859 kg CO2 eq.
Embodied Carbon Hot-Spots 1. CMU 2. Stone Veneer 3. Mineral Wool
8,742 kg 19,273 lbs
ECF
page 15
Double Wood stud assembly ECF
TJI assembly
962 kg CO2 eq.
1,183 kg CO2 eq.
Embodied Carbon Hot-Spots 1. Cement Fiber Board 2. Fiberglass Insulation 3. FG Mat Gypsum Board
Embodied Carbon Hot-Spots 1. TJI 2. Cement Fiber Board 3. OSB
1,601 kg 3,532 lbs
2,018 kg 4,451 lbs
page 16
STUDY OF FIVE SECTIONS MATERIAL TOXICITY + TRANSPARENCY For each product, we reviewed Environmental Product Declarations (EPDs), Health Product Declarations (HPDs), Material Safety Data Sheets (MSDS), and other published product information to evaluate toxicity and transparency.
aSSEMBLY cOMPONENT LIST
A summary of the findings is noted in Table 3. How these findings relate to the material transparency of each wall section can be found in Figure 3 (page 18).
Living Building Challenge v3 Red List
Environmental Product Declaration
Interior Paint: Sherwin Williams: Harmony
Red List Free I10-E4 (9/2012): Proprietary Ingredients
Gypsum Wall Board: USG Fiberrock Abuse Resistant Panels
Red List Free Fully Disclosed
Industry Wide
Spray Foam Insulation: Demilec: Heat Lok Soy 200 Plus
Noncompliant: Foam insulation is not allowed in cavity-fill application as many Red List Free alternatives exist
Industry Wide
Plywood: Roy O’Martin
Exception I10-E11 (1/2009): Composite Wood Sheet Goods
Industry Wide
Air and Vapor Barrier: Vaproshield: Wrap Shield
DECLARE LABEL: Red List Free; Fully Disclosed
Polyiso Insulation: DOW: Thermax CI
Exception I10-E21 (9/2010): HFRs in Foam Insulation (exterior)
Tongue and Groove Siding: Cambia By NFP: FSC Yellow Poplar
Red List Free Fully Disclosed
Exterior Paint: Benjamin Moore Natura
Red List Free I10-E4 (9/2012): Proprietary Ingredients
Wood Studs: Roy O’Martin
Red List Free Fully Disclosed
Industry Wide
page 17
aSSEMBLY cOMPONENT LIST
Living Building Challenge v3 Red List
Environmental Product Declaration
Fiberglass Insulation: Knauf EcoBatt
DECLARE LABEL: Red List Free; Fully Disclosed
Product Specific
Mineral Wool Insulation: Thermafiber Rainscreen HD
Exception I10-E9 (3/2013): Phenol Formaldehyde in Mineral Wool Note - Outside of air barrier
Product Specific
Cement Fiber Board: James Hardie
Red List Free I10-E4 (9/2012): Proprietary Ingredients
Oriented Strand Board: Roy O’Martin
Exception I10-E11 (1/2009): Composite Wood Sheet Goods
Deep TJI: Weyerhaeuser TJI Joist
Exception I10-E10 (8/2008): Structural Composite Wood Members
Cellulose Insulation: GreenFiber Cellulose
DECLARE LABEL: Red List Free; Fully Disclosed
Industry Wide
Metal Z Girts: Clark Dietrich
Red List Free Fully Disclosed
Product Specific
CMU Block: Fizzano Brothers Concrete
Red List Free Fully Disclosed
Stone Veneer: Meshoppen Stone - Bluestone
Red List Free Fully Disclosed
Mat Gypsum Sheathing: USG
Red List Free I10-E4 (9/2012): Proprietary Ingredients
Wood Furring Strips: Roy O’Martin
Red List Free Fully Disclosed
Table 3: Materiality for all Five Wall Assemblies [4]
Industry Wide
page 18
STUDY OF FIVE SECTIONS MATERIAL TOXICITY + TRANSPARENCY
METAL sTUD assembly
wOOD sTUD assembly
cmu assembly
9 PRODUCTS
11 PRODUCTS
6 PRODUCTS
33%
67% 50%
45% 55%
Figure 3: Material Transparency
50%
page 19
dOUBLE wOOD stud assembly
tji assembly
9 PRODUCTS
9 PRODUCTS
33%
67%
33%
67%
Red List or Exception No Red List
page 20
STUDY OF FIVE SECTIONS moisture performance Condensation analysis was performed by SIGA for each wall assembly using USai modeling software. The results determined if condensation would develop in an assembly and, if so, if the assembly would be able to breathe enough to allow the condensation to dry out. This assessment has become increasingly important for high performance assemblies as more insulation is added to building exteriors and smart membranes are used. In each graph, the condensation area is noted by the blue line on the grey bar which is where the Water Pressure line intersects the Saturation Pressure line. Each assembly showed potential condensation in December and January that would dry out within one to four months depending on the assembly. In the case of the CMU assembly, condensation formed because the stone façade was not drying out during the summer months. The value of moisture analysis was seen though SIGA’s analysis which illustrated that an impermeable membrane would needed to protect the CMU rather than a permeable membrane.
Relative humidity [%] 66.8 Interface 2 - 3 gc [g/m²] 20 Ma [g/m²] 20 Ma: accumulated moisture contents Gc: rate of condensation
METAL sTUD assembly
62.1
59.3
-7 13
-52
57.8
62.9
66.3
64.4
67
69.5
68.6
65.2
65.2
-
2.947 page 21
Graphs in equivalent air thickness: January Project:
Vision Architecture_Double Stud
printed on: 9/2/2015 12:04:06 PM
page 3 of 4
Hygrothermal caracteristics First Month: January Interior Temperature [°C] Relative humidity [%] Exterior Temperature [°C] Relative humidity [%] Water [Pa] Interface 5 -presure 6
Jan.
Feb.
Mar.
Apr.
20 71.6
June
20 81.8
July
Aug.
Sept.
Oct.
Nov.
20 59.3
Dec.
20 50.1
20 52.3
20 56.1
20 63.3
20 86.2
20 86.1
20 78.4
20 66.7
-0.039 66.8
2.31 62.1
5.96 59.3
11.9 17 22.4 24.8 57.8 62.9 66.3 64.4 Saturation pressure [Pa]
24.4 67
20.3 69.5
13.4 8.23 2.97 68.6 65.2 65.2 Temperature [°C]
Equivalent air width of the 17 section: gc [g/m²] -16 -74 Ma [g/m²] 17 1 During Summer, the accumulated moisture Ma: accumulated moisture contents Gc: rate of condensation
dOUBLE sTUd assembly
May
20 53.2
6.8 [m]
For special materials you have to check condensed water: - porous materials800 g/m²
Water presure [Pa]
Saturation pressure [Pa]
4.2 [m]
During Summer, the accumulated moisture dries out (March)
-
-
5.286
dries out (March)
The quantity of water condensed in the period -Graphs isn't bigger than 3% from the massJanuary of the wood in equivalent air thickness: - does not exceed 1% of the volume of insulation materials.
Equivalent air width of the section:
Security factor
Temperature [°C]
page 22
STUDY OF FIVE SECTIONS thermal performance An overview of the thermal performance for each wall assembly can be found in Table 4 below..
WALL ASSEMBLY
INSULATION PRODUCTS
TOTAL R-VALUE
Metal Stud
Spray Foam (5 1/2”) Polyiso (1”)
46
Wood Stud
Fiberglass (5 1/2”) Mineral Wool (5”)
43
CMU
Mineral Wool (4”) CMU
19
Double Wood Stud
Fiberglass (10 1/2”)
42
TJI
Cellulose (12”)
44
Table 4: R-Value Total for Each Wall Assembly
page 23
STUDY OF FIVE SECTIONS MATERIAL COST A General Contractor (GC), CVMNEXT Construction worked with us to estimate the cost of each wall assembly and associated products. Prices pertain to January 2015 in the North East region of the US. CVMNEXT, was also able to estimate the price difference between small (10k sf) and large (50k sf) scale building projects.
An estimated cost breakdown for each of the wall assemblies can be found in Table 5. The 10k sf open-shop cost of each assembly was used as an input in the Design Decision Matrix in section 3.2.
WALL ASSEMBLY
OPEN-SHOP 10K SF
OPEN-SHOP 50K SF
Metal Stud
$12,096
$11,773
Wood Stud
$11,447
$11,103
CMU
$14,256
$13,828
Double Wood Stud
$10,150
$9,846
TJI
$9,939
$9,641
Table 5: Cost Analysis of Five Wall Sections
page 24
STUDY OF FIVE SECTIONS END-OF-LIFE An overview of the end of life of the components in each assembly can be found in Table 6.
The last metric used in this research was an assessment of the wall assembly’s end-of-life (EOL). The goal of the EOL is to determine the recyclability and reusability of the products utilized in the assembly. For example, when a building is deconstructed, it is typical that the fiberglass insulation is disposed in a landfill, where as mineral wool can be salvageable for other uses, and gypsum board is sent to a recycling facility. Each of the wall material EOL scenarios was determined by industry practices or information provided by product manufacturers. For products that were commonly sent to either a landfill or recycling facility, a weight was given to both categories when calculating the percentage of landfill versus recycle/salvage. An overview of each material’s EOL can be found in Table 6.
INSULATION
Wall Assembly
Wall Material
END-OF-LIFE SCENARIOS
Cedar Wood Tongue and Groove Siding
Recycle / Landfill
Cement Fiber Board Panel
Salvage / Landfill
Stone Veneer
Recycle / Salvage
WD Furring Strips
Recycle / Salvage
Air and Vapor Barrier
Recycle
Fiberglass Mat Gypsum Sheathing
Salvage / Landfill
Plywood Sheathing
Recycle
Oriented Strand Board
Recycle / Salvage
Metal Z Girts
Recycle
Steel/Metal Stud
Recycle / Salvage
Wood Stud
Recycle / Salvage
CMU Block
Recycle / Salvage
Masonry Anchor Ties
Recycle
Deep TJI
Recycle / Salvage
GWB
Recycle
Interior Paint
Recycle / Landfill
XPS
Salvage / Landfill
Fiberglass
Landfill
Mineral wool
Salvage / Landfill
Spray Foam
Landfill
Cellulose
Landfill
Table 6: End of Life Assessment
page 25
page 26
Metal Stud
STUDY OF FIVE SECTIONS END-OF-LIFE
METAL sTUD assembly
wOOD sTUD assembly
cmu assembly Wood Stud
Metal Stud
16%
14%
17%
27% 33%
42% 59% 42%
50%
Figure 4: Materials End-of-Life
Wood Stud
CMU
Double Wood Stud page 27
CMU
dOUBLE wOOD stud assembly
tji assembly Double Wood Stud TJI
6% 12%
44% 50%
44% 44%
TJI
Landfill Recycle Salvage
page 28
DESIGN DECISION ANALYSIS Based upon the five metrics analyzed in this research we have developed a Design Decision Matrix to more holistically evaluate various wall assemblies. The method for developing this Design Decision Matrix follows:
10-points were assigned to each metric in the Design Decision Matrix for a maximum total of 50 points per assembly. The criteria points were determined by identifying the maximum and minimum of each of the metrics found in the study, and are reflected in Table 7.
qual weights were assumed across all five E metrics in this report. However, the Design Decision Matrix was developed such that the weighting of each metric could be adjusted to represent the needs and goals of the project. For example, you could weight the matrix so that cost, toxicity, and performance were twice as important as end of life and embodied carbon.
page 29
Cost
EFC kg Co2 eq.
Toxicity Red List Items
Thermal Performance R Value
End-of-Life
1
> $15,000
> 4,501
90% Yes or Exception + 10% No
< 20.5
100% Landfill
2
$14,001 to $15,000
4,001 to 4,500
80% Yes or Exception + 20% No
20.6–22
90% Landfill + 10% Recycle or Reuse
3
$13,001 to $14,000
3,501 to 4,000
70% Yes or Exception + 30% No
22.1–24
80% Landfill + 20% Recycle or Reuse
4
$12,001 to $13,000
3,001 to 3,500
60% Yes or Exception + 40% No
24.1–26
70% Landfill + 30% Recycle or Reuse
5
$11,001 to 12,000
2,501 to 3,000
50% Yes or Exception + 50% No
26.1–28
60% Landfill + 40% Recycle or Reuse
6
$10,001 to $11,000
2,001 to 2,500
40% Yes or Exception + 60% No
28.1–30
50% Landfill + 50% Recycle or Reuse
7
$9,001 to $10,000
1,501 to 2,000
30% Yes or Exception + 70% No
30.1–32
40% Landfill + 60% Recycle or Reuse
8
$8,001 to $9,000
1,001 to 1,500
20% Yes or Exception + 80% No
32.1–34
30% Landfill + 70% Recycle or Reuse
9
$7,001 to $8,000
501 to 1,000
10% Yes or Exception + 90% No
34.1–36
20% Landfill + 80% Recycle or Reuse
10
< $7,000
< 500
100% No
> 36
10% Landfill + 90% Recycle or Reuse
Criteria Points
Poor
Fair
Good
Better
Best
Table 7: Design Decision Matrix; ECF is calculated for all products in the wall assembly over the function unit (288 SF).
page 30
DESIGN DECISION ANALYSIS Evaluation of STUDY OF FIVE SECTIONS Overviews of the Design Decision scores are shown in Figure 5. The Design Decision scores reflect an equal weighting across the five metrics. While four out of five of the walls scored high in thermal performance, the double wood stud and the TJI walls were the overall best performers due primarily to their low embodied carbon footprint and low toxicity in their components. Based on the Design Decision Matrix with all of the categories equally weighted, the ranking in descending order are:
1. 2. 3. 4. 5.
TJI Double Wood Stud Wood Stud Metal Stud CMU
page 31
Good
6
7 Better
8
9 Best
10
37
Cost Embodied Carbon Footprint Toxicity: Red List Thermal Performance: R-Value End-of-Life Cost
5
36
Embodied Carbon Footprint Toxicity: Red List Thermal Performance: R-Value End-of-Life Cost
4
21
Embodied Carbon Footprint Toxicity: Red List Thermal Performance: R-Value End-of-Life
Figure 5: Design Decision Scores for the Study of Five Sections
Cost
Fair
34
Embodied Carbon Footprint Toxicity: Red List Thermal Performance: R-Value End-of-Life Cost Embodied Carbon Footprint
2
28 Design Decision Score:
Toxicity: Red List
3
Thermal Performance: R-Value
Poor
End-of-Life 1
TJI Double Wood Stud CMU Wood Stud Metal Stud
page 32
DESIGN DECISION ANALYSIS STUDY OF FIVE SECTIONS conclusion This type of holistic research can help design professionals tie together multiple sustainability metrics. It also illuminates the effects of material choices on the traditional metrics like cost and performance but, also the emerging priorities of environmental impact and health. Process While this study presents results and analysis, it is fundamentally an investigation into the use of tools and a proposed methodology for helping us make better choices about our materials. At the conclusion of this part of the study, we started to ask ourselves how this type of work could be overlaid on the design process. Below is a proposed timeline for this research within the typical design process: Schematic Design 0% - Select criteria for evaluating design decisions. Schematic Design 50% - Conceptualize potential wall assemblies Schematic Design 100% - Use Athena to perform a LCA - Evaluate the results; identify ECF hot spots and alter as necessary. - Perform moisture diffusion modeling; alter as necessary to meet desired performance.
Design Development 50% - Select basis of design products for the assemblies - Conduct end of life research for those products - Begin Red List Research into those products - If an energy model is being used, compare energy usage to the assemblies Design Development 75% - Perform a wall section cost estimate using basis of design products and total project size to reflect any economy of scale in the estimate - Evaluate the costs; eliminate any out of the budget - Aggregate ECF, End of Life, Toxicity, and Cost information into the Design Decision Matrix and select the final assembly
Further Research The study did not directly address the idea of durability or longevity of the assemblies which is an equally important metric when selecting and proposing walls and roofs. Further research into this area is necessary to balance end of life consideration of products and materials.
Barriers to Materials Research
page 33
There are a number of barriers we found in doing this type of work. Below we have listed some of the most common along with some simple suggestions to help you overcome them.
BARRIERS
SUGGESTIONS
Time & Cost: The additional metrics require more research and can compete with other resources needed for project design, construction, and coordination. While important this kind of research is rarely funded by clients.
- Start small. Give yourself an hour to dive as deep as you can into just one metric. Don’t worry if you don’t come to a conclusion; just make yourself smarter for the next time.
Utilizing Tools: Knowing where to find the best resources can become a challenge. Once you have the data, it can be equally difficult to crunch it. Manufacturer Communication: Asking large companies for their ingredient lists or other detailed product information is no easy task. Constant Change: Products and their components are continually changing which makes it difficult to stay current or build a resource library.
- Spread it out. Don’t spend all of your research time on one project. Look for opportunities to look at different metrics on different projects where they will have the most impact. - Use lunch and learns to your advantage. Suggest and target manufactures for presentations that address material environmental and health impacts. - Use your professional memberships. USGBC, Building Green, etc. have multiple webinars on metrics noted in the study. Catch a webinar while you’re eating lunch. - Take short cuts. Use credible 3rd party certifications to identify environmentally responsible products. - Read user manuals and watch how to videos. When the opportunity comes to do some of this work, you’ll already be past the learning curve. - Establish Relationships. For frequently use manufactures, try to reach the same person with your questions and create rapport with them. Ask them to teach you about the ingredients in their product and their function. Help them understand why its important to you.
page 34
NORMALIZED SECTION STUDY
page 35
page 36
NORMALIZED SECTION STUDY Assembly Inventory The second part of the study aimed to compare assembly iterations within three assembly types: wood, metal, and CMU. Each of the wall assembly scenarios includes continuous insulation with a targeted R-value to align with the thermal performance requirements of the International Energy Conservation Code 2013. In each case, this R-value was achieved in a different way and the overall assembly was evaluated for: • • • •
Embodied Carbon Footprint Material Toxicity and Transparency Material Cost End-of-life
Each scenario was based upon the base cases noted in Table 8, with insulation types and thickness as the variable noted in Table 9.
page 37
WOOD STUD ASSEMBLY
METAL STUD ASSEMBLY
CMU ASSEMBLY
Metal Cladding Exterior Insulation Air and Vapor Barrier Plywood Sheathing Cavity Insulation Wood Stud GWB Interior Paint
Metal Cladding Exterior Insulation Air and Vapor Barrier Plywood Sheathing Cavity Insulation Steel Stud GWB Interior Paint
Metal Cladding Exterior Insulation Metal Z Girts Air and Vapor Barrier CMU Block GWB Interior Paint
METAL STUD CASES
CMU CASES
Table 8: Normalized Wall Assembly Breakdown
WOOD STUD CASES Case 1: 1” XPS + 3 1/2” FG R-5 + R-15 =R-20
Case 1: 2” XPS + 3 1/2” FG R-10 + R-13= R-23
Case 2: 1 1/2” MW + 3 1/2” FG R-6.3 + R-15= R-21
Case 2: 2” MW + 3 1/2” FG R-8.4 + R-13= R-21
Case 3: 1” XPS + 2” SF R-5 + R-15 = R-20
Case 3: 2” XPS + 2” SF R-10 + R-14.8= R-25
Case 4: 1 1/2” MW + 2” SF R-6.3 + R-14.8= R-21
Case 4: 2” MW + 2” SF R-8.4 + R-14.8= R-23
Case 5: 1” XPS + 3 1/2” Cell R-5 + R-13= R-18
Case 5: 2” XPS + 3 1/2” Cell R-10 + R-13= R-23
Case 6: 1 1/2” MW + 3 1/2” Cell R-6.3 + R-13= R-19
Case 6: 2” MW + 3 1/2” Cell R-8.4 + R-13= R-21
Table 9: Insulation Combinations Tested for Each Wall Assembly
XPS: Extruded Polystyrene
Case 1: 2” XPS R-10 Case 2: 2 1/2” MW R-10.5
MW: Mineral Wool FG: Fiberglass SF: Spray Foam
page 38
NORMALIZED SECTION STUDY Embodied Carbon footprint Athena Impact Estimator for Buildings Inputs in Normalized study
Three wall types were studied: metal stud, wood stud, and CMU.An overview of the life cycle inputs from Athena can be found in Table 10.
- - - -
The wall section has an area of 12’ x 24’ (functional unit) 50 year time span Average USA data Cradle to gate analysis
page 39
INSULATION
Wall Assembly
Wall Material
Athena Input
Metal Cladding 26 GA
Metal Wall cladding 26 GA
Air and Vapor Barrier
Air Barrier
Metal Z Girts
Bolts Fastners clips
Plywood Sheathing
Softwood Plywood
Steel Stud
Galvanized Studs
Wood Stud
Small Dimension Softwood Lumber, kiln-dried
CMU Block
8" concrete block
GWB
5/8" Regular Gypsum Board
Interior Paint
Solvent Based Alked paint
XPS
Extruded Polystyrene
Fiberglass
FG Batt R 11-15
Mineral wool
MW Batt R 11-15
Spray Foam
Hand calculation
Cellulose
Blown Cellulose
Table 10: Athena Life Cycle Unit Processes
page 40
NORMALIZED SECTION STUDY Embodied Carbon footprint Life Cycle Impact Assessment: Embodied Carbon Footprint (ECF) The weight and embodied carbon for the materials used in each of the normalized wall sections can be found in Figure 6. - The material weight is consistent for each of the six insulation cases within the three wall assembly scenarios, averaging 2.0 (Wood Stud), 1.2 (Metal Stud), and 7.9 (CMU) short tons respectively (shown in Figure 6). The embodied carbon footprint impact ranges depending on the insulation combinations within each of the wall assembly scenarios. Out of the five insulation types analyzed, spray foam has the highest embodied carbon footprint across each wall assembly scenario. - Wood Stud Assembly Base ECF: 1,458 kg of CO2 eq - Case 1, 2, 4 and 6, averaged 2,291 kg of CO2 eq. - Case 3 and 4 averaged 3,692 kg of CO2 eq. or 38% higher than the other insulation cases. - Metal Stud Assembly Base ECF: 1,520 kg of CO2 eq - Cases 1, 2, 5, and 6 averaged 2,320 kg of CO2 eq. - Cases 3 and 4 averaged 3,721 kg of CO2 eq. or 40% higher.
- CMU Assembly Base ECF: 2,451 kg of CO2 eq - Cases 1, 2, 5, and 6 averaged 3,341 kg of CO2 eq. - Cases 3 and 4 averaged 4,743 kg of CO2 eq. or 30% higher. - With regard to the five different insulation products used in this study, spray foam has a significantly larger ECF than the other four. The XPS and mineral wool insulation used in this study are comparable to each other, followed by fiberglass insulation and cellulose. Cellulose had the lowest ECF, averaging 19 kg of CO2 eq. in each of the wall assembly cases.
page 41
wood stud
Metal stud
CMu 4000
9
Cellulose
8
3500 Spray Foam
Embodied carbon
5
4
2500
2000
1500 3
2
weight
weight (metric tons) Weight of Wall Section (tonnes)
6
1000
500
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Figure 6: Material Breakdown of Wall Assembly Scenarios. Left - Weight in Tonnes; Right- Embodied Carbon Footprint in kg CO2 eq.; XPS = Extruded Polystyrene, FG = Fiber Glass, SF = Spray Foam, MW = Mineral Wool, Cell = Cellulose
27
28
Case 2 MW
12
Case 1 XPS
11
0
Case 6 MW + Cell
10
Case 5 XPS + Cell
9
Case 4 MW + SF
8
Case 3 XPS + SF
7
Case 2 MW + FG
6
Case 1 XPS + FG
5
Case 4 MW + SF
4
Case 3 XPS + SF
3
Case 2 MW + FG
2
Case 1 XPS + FG
1
Case 6 MW + Cell
0
Case 5 XPS + Cell
1
Fiberglass
Embodied Carbon Footprint (kg of CO2 eq.)
3000
embodied carbon (kg CO2 eq.)
7
wood stud
Mineral Wool XPS Interior Paint GWB CMU Block Metal Stud Wood Stud Plywood Sheathing Air & Vapor Barrier Metal Z Girts Metal Cladding
page 42
NORMALIZED SECTION STUDY MATERIAL TOXICITY + TRANSPARENCY Environmental Product Declarations (EPDs), Health Product Declarations (HPDs), Material Safety Data Sheets (MSDS), and other published product information were used to evaluate product’s toxicity and transparency. A summary of these findings per product can be found in Table 11.
page 43
aSSEMBLY cOMPONENT LIST
Living Building Challenge v3 Red List
Environmental Product Declaration
Metal Cladding 26 GA: Englert
Red List Free - Unintentional Trace Amounts: Recycled Materials
Air and Vapor Barrier: Vaproshield: Wrap Shield
I10-E4 (9/2012): Proprietary Ingredients
Plywood: Roy O’Martin
Exception I10-E11 (1/2009): Composite Wood Sheet Goods
Metal Studs: Clark Dietrich
Red List Free Fully Disclosed
Wood Studs: Roy O’Martin
Red List Free Fully Disclosed
CMU Block: Fizzano Brothers Concrete Products
Red List Free Fully Disclosed
Gypsum Wall Board: USG Fiberrock Abuse Resistant Panels
Red List Free Fully Disclosed
Interior Paint: Sherwin Williams: Harmony
I10-E4 (9/2012): Proprietary Ingredients
Polyiso Insulation: DOW: Thermax CI
Exception I10-E21 (9/2010): HFRs in Foam Insulation exterior insulation
Industry Wide
Fiberglass Insulation: Knauf EcoBatt
DECLARE LABEL: Red List Free; Fully Disclosed
Product Specific
Mineral Wool Insulation: Thermafiber Rainscreen HD
Exception I10-E9 (3/2013): Phenol Formaldehyde in Mineral Wool Note - Outside of air barrier
Product Specific
Spray Foam Insulation: Demilec: Heat Lok Soy 200 Plus
Noncompliant: Foam insulation is not allowed in cavity-fill application as many Red List Free alternatives exist
Industry Wide
Cellulose Insulation: GreenFiber Cellulose
DECLARE LABEL: Red List Free; Fully Disclosed
Industry Wide
Table 11: Transparency Documentation for Normalized Wall Assemblies Components
Industry Wide
Industry Wide
Industry Wide
NORMALIZED SECTION STUDY thermal performance
METAL STUD
WOOD Stud
WALL ASSEMBLY
CMU
page 44
INSULATION COMBINATION
EXTERIOR R VALUE
INTERIOR R VALUE
TOTAL R VALUE
1
5
15
20
2
6.3
15
21.3
3
5
14.8
19.8
4
6.3
14.8
21.1
5
5
13
18
6
6.3
13
19.3
1
10
13
23
2
8.4
13
21.4
3
10
14.8
24.8
4
8.4
14.8
23.2
5
10
13
23
6
8.4
13
21.4
1
10
2
12
2
10.5
2
12.5
Table 12: R-Value Total for each of the Insulation Combinations
Each of the wall assembly scenarios targeted the thermal performance requirements of International Energy Conservation Code 2013. An overview of the thermal performance for each of the insulation combinations for the wall assembly cases, as described in Table 8, can be found in Table 12.
NORMALIZED WALL SECTION STUDY MATERIAL COST A General Contractor (GC), CVMNEXT Construction worked with us to estimate the cost of each wall assembly and associated products. Prices pertain to January 2015 in the North East region of the US. CVMNEXT, was also able to estimate the price difference between small (10k sf) and large (50k sf) scale building projects.
An estimated cost breakdown for each of the wall assemblies can be found in Figure 7. The 10k sf open-shop cost of each assembly was used as an input in the Design Decision Matrix in section 3.2.
14000 Interior Paint GWB
12000
CMU Block Steel Stud (2x4)
10000
Cost ( $ )
Wood Stud (2x4) Cellulose
8000
Spray Foam Fiberglass Insulation
6000
Plywood Sheathing Air and Vapor Barrier
4000
Mineral Wool (2.5") Mineral Wool (1.5")
2000
XPS (2") XPS (1")
0 1
2
3
4
5
6
1
Metal Stud Figure 7: Cost Analysis of Normalized Wall Section Study
2
3
4
Wood Stud
5
6
1
2
CMU
Metal Cladding
page 45
page 46
NORMALIZED SECTION STUDY END-OF-LIFE (EOL) Each of the wall material EOL scenarios was determined by industry practices or information provided by product manufacturers. For products that were commonly sent to either a landfill or recycling facility, a weight was given to both categories when calculating the percentage of landfill versus recycle/salvage. An overview of each material’s EOL can be found in Table 13.
page 47
INSULATION
Wall Assembly
Wall Material
END-OF-LIFE SCENARIOS
Metal Cladding 26 GA
Recycle
Air and Vapor Barrier
Landfill
Metal Z Girts
Recycle / Salvage
Plywood Sheathing
Recycle
Steel Stud
Recycle / Salvage
Wood Stud
Recycle / Salvage
CMU Block
Recycle / Salvage
GWB
Recycle
Interior Paint
Recycle / Landfill
XPS
Salvage / Landfill
Fiberglass
Landfill
Mineral wool
Salvage / Landfill
Spray Foam
Landfill
Cellulose
Landfill
Table 13: Normalized Wall Study End-of-Life Scenarios
page 48
DESIGN DECISION ANALYSIS A Design Decision Matrix was developed for the four metrics analyzed in the Normalized wall assembly study: cost, ECF, toxicity, and EOL (see Table 14). Thermal performance was not included in the Design Decision Matrix since each of the wall assemblies were designed to IECC 2013. The scoring method for the Design Decision Matrix is as follows:
10-points were assigned to each metric in the Design Matrix for a maximum total of 40 points per assembly. The criteria points were determined by assessing the maximum and minimum of each of the metrics found in the study.
qual weights was assumed across all E four metrics in this report. However, the Design Decision Matrix was developed such that the user and/or client could adjust the weighting of each metric to represent the needs and goals of the project. For example, you could weigh the matrix so that cost, toxicity, and performance where twice as important as end of life and embodied carbon.
page 49
Criteria Points
Cost
EFC kg Co2 eq.
Toxicity Red List Items
End-of-Life
1
> $15,000
> 4,501
90% Yes or Exception + 10% No
100% Landfill
2
$14,001 to $15,000
4,001 to 4,500
80% Yes or Exception + 20% No
90% Landfill + 10% Recycle or Reuse
3
$13,001 to $14,000
3,501 to 4,000
70% Yes or Exception + 30% No
80% Landfill + 20% Recycle or Reuse
4
$12,001 to $13,000
3,001 to 3,500
60% Yes or Exception + 40% No
70% Landfill + 30% Recycle or Reuse
5
$11,001 to 12,000
2,501 to 3,000
50% Yes or Exception + 50% No
60% Landfill + 40% Recycle or Reuse
6
$10,001 to $11,000
2,001 to 2,500
40% Yes or Exception + 60% No
50% Landfill + 50% Recycle or Reuse
7
$9,001 to $10,000
1,501 to 2,000
30% Yes or Exception + 70% No
40% Landfill + 60% Recycle or Reuse
8
$8,001 to $9,000
1,001 to 1,500
20% Yes or Exception + 80% No
30% Landfill + 70% Recycle or Reuse
9
$7,001 to $8,000
501 to 1,000
10% Yes or Exception + 90% No
20% Landfill + 80% Recycle or Reuse
10
< $7,000
< 500
100% No
10% Landfill + 90% Recycle or Reuse
Poor
Fair
Good
Better
Best
Table 14: Design Decision Matrix; ECF is calculated for all products in the wall assembly over the function unit (288 SF).
page 50
DESIGN DECISION ANALYSIS Design Decision of NORMALIZED Wall Sections Findings: An overview of the Design Decision Matrix scores is shown in Figure 8. The Design Decision scores reflect an equal weighting across the four metrics. Below is the total embodied carbon footprint of each insulation combination.
WOOD STUD ASSEMBLIES
METAL STUD ASSEMBLIES
Case 1: 1” XPS + 3 1/2” FG (R-20) 169 kg of CO2 eq
Case 1: 2” XPS + 3 1/2” FG (R-23)
Case 2: 1 1/2” MW + 3 1/2” FG (R-21)
Case 2: 2” MW + 3 1/2” FG (R-21)
144 kg of CO2 eq Case 3: 1” XPS + 2” SF (R-20)
1,587 kg of CO2 eq Case 4: 1 1/2” MW + 2” SF (R-21)
1,562 kg of CO2 eq Case 5: 1” XPS + 3 1/2” Cell (R-18)
130 kg of CO2 eq Case 6: 1 1/2” MW + 3 1/2” Cell (R-19)
104 kg of CO2 eq
278 kg of CO2 eq 171 kg of CO2 eq Case 3: 2” XPS + 2” SF (R-25)
1,696 kg of CO2 eq Case 4: 2” MW + 2” SF (R-23)
1,589 kg of CO2 eq Case 5: 2” XPS + 3 1/2” Cell (R-23)
239 kg of CO2 eq Case 6: 2” MW + 3 1/2” Cell (R-21)
132 kg of CO2 eq
CMU ASSEMBLIES Case 1: 2” XPS (R-10)
220 kg of CO2 eq Case 2: 2 1/2” MW (R-10.5)
141 kg of CO2 eq
page 51
30
26
25
20
20
25
23
25
25
6
6
19
19
23
24
22
21
25 6
6
6
20
6 6
15
5 6
6
6
6
5
6 5
6 5
10
6
6
7
7 4
7
7
6
4
6
6
Case 2
Case 3
5
6
5
6 EndͲofͲLife
6
Red List Items
4
6
6
Case 1
Case 2
5
6
5 7
5 7
6
6 5
5
7
6
7
5
5
4
4
5
5
5
Case 5
Case 6
Case 1
4
0 Case 1
Case 4
Case 5
Case 6
Wood Stud Figure 8: Design Decision Matrix Scores for Normalized Wall Study
Case 3
Case 4
Metal Stud
Case 2 CMU
ECF (kg CO2 eq.) Cost ($)
page 52
DESIGN DECISION ANALYSIS NORMALIZED Wall Section study conclusion In this portion of the study we chose to isolate insulation in this analysis as it is the component in a wall assembly that has the greatest effect on the project’s operating energy. We wanted to determine how much it contributed to the other categories described in the study and thus, which insulation is the most environmentally preferred. In the proposed assemblies, the wood stud and metal stud walls composed of XPS and mineral wool on the exterior and fiberglass or cellulose insulation in the cavity scored the highest across all wall assemblies. Many of the insulation combinations, noted on the previous pages are within Athena’s margin of error difference of 15%, making them essentially the same in terms of embodied carbon footprint.
Some final thoughts on insulation: Cellulose and fiberglass have low embodied carbon footprint and toxicity but, cellulose can be expensive and both fiberglass and cellulose must be disposed of in a landfill at this time. Spray Foam, while it has a very high insulating value per inch, it performed poorly across the metrics evaluated. XPS insulation performed poorly when it came to embodied carbon footprint and toxicity but, did well from a cost and end of life perspective. Mineral wool was performed average in embodied carbon footprint, toxicity, and cost; and the best under end of life.
FINAL THOUGHTS & REFERENCES While “Thinking in Assemblies” presents research and findings, the realities of design, construction, and budget will often dictate the selection of some of the materials in any project. It is our hope that some of the ideas presented in this study have caught your interest and will one day help inform some of your work so that product selection in this new materials economy is not only defined by a limited number of factors but, a thoughtful investigation across multiple attributes that impact performance, the environment, and human health. We definitely learned from this study, and will carry our lessons learned into future work. We welcome feedback and look forward to having a conversation with you.
ACKNOWLEDGEMENTS Thank you to Chris Boccella (CVMnext) for his support on material estimates, and Garrett McKissock (SIGA) for his support on moisture transport analysis using USai. References 1 - SPFA. Life Cycle Assessment of Spray Polyurethane Foam Insulation for Residential and Commercial Building Applications. Tech. Fairfax, VA: Spray Foam Polyurethane Foam Alliance, 2012. Print. 2 - “U.S. Life Cycle Inventory Database.” (2012). National Renewable Energy Laboratory, 2012. Accessed December 2012: https://www.lcacommons.gov/nrel/search 3 - Bushi, Lindita, Grant Finlayson, and Jamie Meil. A Cradleto-Gate Life Cycle Assessment of Ready Mixed Concrete Manufacture by NRMCA Members. Tech. N.p.: Athena Sustainable Materials Institute, 2014. Print. 4 - “Declare Products.” Product Database. International Living Future Institute, 2011. Web. 14 Dec. 2015.
page 53